K-DRS ELK GERAETESTECKER

Pressure switches, connection with plug connector, type A acc. to DIN 43650
Switching frequency
200/min. 
Switching voltage
max. 250 V AC / 28 V DC 
Protection IP
IP 65 (DIN 43650), IP 67 (M 12 x 1) 
Download PDF

Please choose a variant

Rodyti prekių lentelę
Registruokitės dabar, kad pasiektumėte mūsų internetinę parduotuvę.

Register now and access our complete product range and many exclusive services.

Characteristics

Switching frequency
  • 200/min. 
Switching voltage
  • max. 250 V AC / 28 V DC 
Protection IP
  • IP 65 (DIN 43650), IP 67 (M 12 x 1) 
Diaphragm, seal
  • NBR 
Setting cap
  • aluminium powder coated 
Application
  • pneumatic applications 
Housing
  • special die-cast 
Temp. range
  • -10 °C to +80 °C 
All characteristics

Gaminio aprašymas

Notes
Further information on request.
Description
For converting pneumatic to electrical signals. The switching point can be continuously adjusted with the adjustment knob. Universal switch type, suitable as NC, NO or changeover contact. These devices are free from paint-wetting impairment substances (PWIS).

Product variants

3 Results
Show dimensional drawing
Identifier
Connecting thread
A (mm)
B (mm)
Setting range
G 1/4″ -19 
48 mm
28 mm
0,2 - 2,0 bar 
G 1/4″ -19 
48 mm
28 mm
0.5 - 8.0 bar 
G 1/4″ -19 
48 mm
28 mm
1,0 - 16,0 bar 

Column selection

Connecting thread
A (mm)
B (mm)
Setting range